At Hebei Leeter's Dingzhou, Hebei and Tay Ninh, Vietnam plants, we manufacture both pre-galvanized and full HDGAW welded mesh temporary fence, chain-link temporary fence and steel-tube crowd control barriers to AS 4687-2007 and UK/EU/North American standards.

What is the metallurgical difference between Pre-Galvanized and HDGAW panels?
Every welded temporary fence panel — whether an Australian 2.1 × 2.4 m (6.9 × 7.9 ft) panel, a European 2.0 × 3.5 m (6.6 × 11.5 ft) Heras panel, or a North American 6 × 10 ft / 6 × 12 ft (1.83 × 3.05/3.66 m) panel — has 4 corner tube welds, 1 to 2 center brace welds, and 60 to 110 mesh-to-frame perimeter welds.
- Pre-Galvanized (Welded from Pre-Coated Strip & Wire): The mill starts with pre-galvanized steel strip rolled into 32 mm or 38 mm OD tube (typically 40–80 g/m² zinc) and pre-galvanized mesh wire (30–60 g/m²). When the welders MIG-weld the frame corners and spot-weld the mesh infill onto the tube, the 1,500 °C welding arc vaporizes the zinc coating at every joint. Workers then wire-brush the slag and spray cold zinc-rich या silver aluminum paint over the burned welds.
- Hot-Dip Galvanized After Welding (HDGAW / Full Dip): The entire panel is fabricated from bare cold-rolled tube and hard-drawn black wire, pickled in hydrochloric acid, fluxed, and submerged whole into a 450 °C (842 °F) molten zinc kettle. The molten zinc forms three metallurgical Fe-Zn alloy layers plus a pure zinc outer layer (42 to 70+ microns / 300 to 500 g/m²) that encapsulates every weld bead, corner gusset and internal tube wall.
Head-to-head specification & 5-year TCO comparison matrix
| Engineering & Commercial Parameter | Economy Pre-Galvanized + Sprayed Welds | Standard Pre-Galvanized (Heavy Z180/Z275) | Full Hot-Dip Galvanized After Welding (HDGAW) |
|---|---|---|---|
| Tube & Mesh Zinc Mass | 40–60 g/m² (6–9 µm / 0.13–0.20 oz/ft²) | 120–200 g/m² (17–28 µm / 0.40–0.65 oz/ft²) | ≥300–450 g/m² (42–65 µm / 1.00–1.50 oz/ft²) |
| Weld Joint Protection | Cold silver paint / zinc spray (peels in 6–12 mo) | Cold zinc-rich primer (85%–92% Zn dry film) | 100% continuous metallurgical zinc bath seal |
| Weld Shear & Frame Rigidity | Mesh spot-welds prone to popping if paint hides cold welds | Good initial strength; corner welds corrode first | Weld shear ≥ 2.5 kN; zinc alloy reinforces fillet joints |
| Time to First Red Rust at Welds | 3–9 months outdoors (coastal: 4–8 weeks) | 12–24 months outdoors | 7–12+ years outdoors (AS 4687 / EN ISO 1461) |
| Expected Fleet Redeployments | 3–6 site cycles before frame weld failure | 8–14 site cycles | 25–40+ site cycles |
| Relative FOB Unit Cost Index | 1.00× (Lowest upfront price) | 1.10× – 1.15× | 1.20× – 1.28× |
| 5-Year Amortized Cost per Deployment | $4.50 – $6.80 / panel-cycle (high scrap rate) | $2.80 – $3.60 / panel-cycle | $1.15 – $1.65 / panel-cycle (Lowest TCO) |
When to buy Pre-Galvanized vs HDGAW temporary fencing
When Pre-Galvanized (GBW + Sprayed Welds) is the right choice:
- Single-project general contractors buying panels for a 12-to-18-month build where the fence will be written off or sold as used surplus at handover.
- High-turnover retail / wholesale yards competing on entry-level piece price in dry inland climates (e.g., inland Southwest US, Middle East interior) where panels are not tossed on and off rental flatbed trucks every month.
- Container-volume advantage: Because pre-galvanized Heras panels (3.5 × 2.0 m) do not warp in a 450 °C zinc kettle, they can be built with thinner 1.2–1.5 mm tube walls, loading 450–520 panels per 40HQ.
When Full Hot-Dip Galvanized After Welding (HDGAW) is mandatory:
- Fence rental fleets & plant-hire companies: Rental panels endure forklift tines, ratchet straps, concrete splatter and 6–10 loadings/unloadings per year. Only a ≥42 µm (300 g/m²) metallurgical hot-dip coating survives repeated impact without flaking.
- Australian & New Zealand compliance (AS 4687-2007): Australian temporary fencing fleets specify 2.1 × 2.4 m panels with 32/38 mm OD × 1.6–2.0 mm wall tube and ≥42 microns HDG coating verified by magnetic Elcometer gauge.
- Coastal, municipal and data-center projects: Where rust streaks on public sidewalks or premature weld breakage under wind loading triggers inspector citations.
3 inspection tests to verify HDGAW vs fake "full galvanized" quotes
Unscrupulous suppliers frequently quote "Hot-Dip Galvanized Temporary Fence" when they actually mean weld-fabricated from hot-dip pre-galvanized pipe with silver spray paint on the joints. Verify the difference in 30 seconds:
- Inspect the Corner Saddle Welds & Drain Holes: A true HDGAW panel has 6–8 mm zinc-vent / drainage holes drilled inside the frame corners (to prevent tube explosion in the 450 °C zinc bath) and a continuous crystalline zinc spangle across the weld bead with zero silver spray-paint overspray.
- Magnetic Coating Thickness Gauge (Elcometer / PosiTector): Place the probe directly on the mesh wire, the tube body, and 10 mm from the corner weld. True HDGAW reads 42 to 75 microns everywhere; pre-galvanized tube reads 8 to 22 microns on the pipe and 0 microns (or paint thickness) on the weld.
- Panel Net Weight Check: Dipping a panel in molten zinc requires a minimum 1.5 to 2.0 mm tube wall (thinner 1.0–1.2 mm tube buckles in the 450 °C kettle) and adds 1.2 to 1.8 kg (2.6 to 4.0 lbs) of pure zinc mass per panel.
Frequently asked questions
Why do pre-galvanized temporary fence panels always rust at the corners first?
During welding, the 1,500 °C electric arc burns off the thin 6–15 µm pre-galvanized zinc layer at every tube joint and mesh-to-frame spot weld. Even when the factory brushes the weld and sprays cold zinc or silver paint over the joint, the paint has no metallurgical bond and cracks under frame flex during the first few truck deliveries.
What is the minimum tube wall thickness required for hot-dip galvanizing after welding?
To prevent frame warping and distortion when submerged in a 450 °C (842 °F) molten zinc kettle, the outer frame tube (32 mm, 38 mm or 42 mm OD) should have a minimum wall thickness of 1.50 to 2.00 mm (16 to 14 gauge), paired with 3.5 to 4.5 mm cold-drawn infill mesh wire.
Can we ship panels from your Vietnam factory to avoid China antidumping duties?
Yes. In addition to our Dingzhou, Hebei plants, our joint-venture facility UNION TOP METAL (VIET NAM) LTD in Tay Ninh Province, Vietnam (in production since May 2026) manufactures temporary fence panels, wire fence and tie wire with Vietnam origin. Contact our export desk with your HTS code and destination port to confirm rules-of-origin documentation with your customs broker.
Manufactured by Hebei Leeter Import and Export Co., Ltd., operating dedicated tube-welding, mesh-welding and hot-dip galvanizing facilities in Dingzhou, Hebei, China and Tay Ninh Province, Vietnam under ISO 9001:2015.